原子能科学技术Issue(3):500-505,6.DOI:10.7538/yzk.2014.48.03.0500
直流X射线模拟电缆X射线响应的可行性
Feasibility of Using Continuous X-ray to Simulate Cable Response Under X-ray Environment
马良 1周辉 1程引会 1吴伟 1李进玺 1赵墨 1郭景海1
作者信息
- 1. 西北核技术研究所 强脉冲辐射环境模拟与效应国家重点实验室,陕西 西安 710024
- 折叠
摘要
Abstract
The mechanism and simulating method of cable response induced by X-ray were researched ,and the relationship of cable response irradiated by continuous and pulsed X-ray was analyzed .A one-dimension model of strip line irradiation response of X-ray was given , which includes the gap between cable shield and dielectric , and induced conductivity in cable dielectric .The calculation result using the model indicates that the cable responses of continuous and rectangular-pulsed X-ray have the similar current waveform and the same gap voltages .Therefore ,continuous X-ray can be used to research some cable responses of pulsed X-ray irradiation under the mechanism described in the one-dimension model .关键词
直流X射线/电缆/X射线辐照响应/脉冲X射线Key words
continuous X-ray/cable/X-ray irradiation response/pulsed X-ray分类
数理科学引用本文复制引用
马良,周辉,程引会,吴伟,李进玺,赵墨,郭景海..直流X射线模拟电缆X射线响应的可行性[J].原子能科学技术,2014,(3):500-505,6.