中国电机工程学报Issue(27):1-11,11.
三相并网逆变器内模控制的改进型GDPWM算法
A Modified GDPWM Algorithm Based on Internal Model Control for Three-phase Grid-connected Inverters
摘要
Abstract
The internal model control equation of a three-phase grid-connected inverter with a unitary power factor was deduced. The function relationship between the power factor angle and output current at the inverter side was studied. The characteristic of traditional general discontinuous pulse width modulation (GDPWM) was analyzed in detail. A modified GDPWM (M-GDPWM) algorithm with the minimum switching loss was proposed in this paper. Zero-sequence voltage components injected into three-phase sinusoidal reference voltages were generated by comparing instantaneous three-phase sinusoidal reference voltages, or by judging instantaneous three-phase output currents at the inverter side, rather than calculating the power factor angle to minimize switching loss in the traditional GDPWM algorithm. Simulation and experimental results verify the correctness and validity of the proposed M-GDPWM.关键词
三相并网逆变器/内模控制/不连续脉宽调制/功率因数角Key words
three-phase grid-connected inverter/internal model control/discontinuous pulse width modulation (DPWM)/power factor angle分类
信息技术与安全科学引用本文复制引用
安少亮,孙向东,张琦,钟彦儒,任碧莹..三相并网逆变器内模控制的改进型GDPWM算法[J].中国电机工程学报,2013,(27):1-11,11.基金项目
陕西省重点学科建设基金(105-5X1201);高等学校博士学科点专项科研基金(20116118110006)。Project Supported by Shaanxi Provincial Project of Special Foundation of Key Disciplines (105-5X1201) (105-5X1201)
Special Scientific and Research Funds for Doctoral Speciality of Institution of Higher Learning (20116118110006) (20116118110006)