| 注册
首页|期刊导航|中国医学创新|尿干化学分析仪测定与显微镜镜检结果分析

尿干化学分析仪测定与显微镜镜检结果分析

朱慧

中国医学创新Issue(2):69-71,3.
中国医学创新Issue(2):69-71,3.DOI:10.3969/j.issn.1674-4985.2014.02.034

尿干化学分析仪测定与显微镜镜检结果分析

Analysis of Urine Dry Chemical Analyzer and Microscopic Examination Results

朱慧1

作者信息

  • 1. 上海市崇明县传染病医院 上海 202150
  • 折叠

摘要

Abstract

Objective:To compared the results of two methods of urine dry chemistry methods and microscopic examination,to contact the clinical rational analytical results. Method:Used dry chemistry methods and sediment mirror detected urine white blood cell(leucocyte),urine hemoglobin(Hb), red blood cell(RBC)in patients,the detection results of the two methods were compared and analyzed. Result:The experimental data showed that the results of chemistry methods and microscopic examination results were not consistent with the situation,both negative,positive results had the phenomenon of cross. Conclusion:Combined use of urine dry chemical method to check with the sediment microscopy can increase the value of clinical application.

关键词

尿干化学法/镜检法/尿白细胞/尿血红蛋白/尿红细胞/方法比较

Key words

Urine dry chemistry method/Microscopic examination/White blood cells in urine/Hemoglobin in urine/Red blood cells in urine/Comparison of methods

引用本文复制引用

朱慧..尿干化学分析仪测定与显微镜镜检结果分析[J].中国医学创新,2014,(2):69-71,3.