| 注册
首页|期刊导航|中国医学装备|多间距视网膜表面微电极阵列设计与特性测试

多间距视网膜表面微电极阵列设计与特性测试

崔红岩 郝玲玲 陈俪行 胡勇 徐圣普 冯莉 谢小波

中国医学装备Issue(4):1-3,4,4.
中国医学装备Issue(4):1-3,4,4.DOI:10.3969/J.ISSN.1672-8270.2014.04.001

多间距视网膜表面微电极阵列设计与特性测试

Design and feature test of multi-distance epi-retinal microelectrode

崔红岩 1郝玲玲 1陈俪行 2胡勇 1徐圣普 1冯莉 1谢小波1

作者信息

  • 1. 中国医学科学院北京协和医学院生物医学工程研究所 天津 300192
  • 2. 香港城市大学生物医学工程系 香港 999077
  • 折叠

摘要

Abstract

Objective:To optimize the design and fabrication of epi-retinal microelectrode array for the retain vision of RP and AD patients, multi-distance flexible electrode array was designed and fabricated. Electro-chemical feature test of the array was performed.Methods:Parylene with flexibility and biocompatibility was used as substrate material and Au was used as electrode material. Multi-distance microelectrode array was designed and fabricated, and then mechanical property and flexibility of the array were tested.Results: Mechanical property and flexible test results showed that the fabricated microelectrode array fulfilled the design requirement.Conclusion: The designed and fabricated array can be put into animal experiment for optimization design of the array by obtaining in vivo electro-physiological test results.

关键词

视网膜表面微电极阵列/视觉假体/优化设计

Key words

Epi-retinal microelectrode/Retinal prosthesis/Optimization design

分类

医药卫生

引用本文复制引用

崔红岩,郝玲玲,陈俪行,胡勇,徐圣普,冯莉,谢小波..多间距视网膜表面微电极阵列设计与特性测试[J].中国医学装备,2014,(4):1-3,4,4.

基金项目

国家自然科学基金(81271667)“视网膜微电极植入动物体后受内环境电生理因素影响的仿真研究”;天津市科技支撑计划重点项目(10zckfsy08400)“视网膜表面微电极阵列的研制和动物实验研究” (81271667)