Objective:To compare hypothermia treatment and conventional treatment for severe traumatic brain injury patients with acute traumatic coagulopathy the clinical therapeutic effect of hypothermia treatment to explore the clinical value.Methods: A hospital sTBI merger ATC 100 patients were randomly divided into experimental and control groups, the experimental group were taken hypothermia treatment in the control group of patients taking conventional treatment. Measuring experimental group and control group of patients at different stages of FIB, TT, APTT, PT, and D-dimer levels, while the patient's vital signs, oxygen saturation, blood electrolytes, blood pressure, intracranial pressure and complications testing records.Results: The results showed that the experimental group were FIB, TT, APTT, PT, D-dimer levels and vital signs, oxygen saturation, serum electrolytes, blood gas analysis and other patients with no significant difference between the control group; However, the experimental group of patients with intracranial pressure was significantly lower than the control group(t=4.76,t=9.87,t=8.92;P<0.01).Conclusion: sTBI combined use of mild hypothermia treatment in patients with ATC compared to conventional treatment does not pose a risk, but it also significantly lower in patients with intracranial pressure, brain tissue of the patient play a protective role.

关键词

亚低温/重型颅脑创伤/急性创伤性凝血病/应用价值

Key words

Mild hypothermia/Severe head trauma/Acute traumatic coagulopathy/Application value

分类

医药卫生

引用本文复制引用

周军,杨丽,于宝占,王明钢..亚低温对重型颅脑创伤合并急性创伤性凝血病影响的临床研究[J].中国医学装备,2014,(4):98-99,100,3.

中国医学装备

OACSTPCD

1672-8270

访问量3
|
下载量0
段落导航相关论文