| 注册
首页|期刊导航|中国中西医结合影像学杂志|多方法检测肱-踝动脉脉搏波传导速度的比较研究

多方法检测肱-踝动脉脉搏波传导速度的比较研究

任亚娟 肖沪生 徐芳 银浩强 高东雯 王奇

中国中西医结合影像学杂志Issue(2):116-118,3.
中国中西医结合影像学杂志Issue(2):116-118,3.DOI:10.3969/j.issn.1672-0512.2014.02.002

多方法检测肱-踝动脉脉搏波传导速度的比较研究

Comparative study on the detection of brachial ankle pulse wave velocity by multi-method

任亚娟 1肖沪生 1徐芳 1银浩强 1高东雯 1王奇1

作者信息

  • 1. 上海中医药大学附属龙华医院超声科,上海200032
  • 折叠

摘要

Abstract

Objective:To explore the feasibility and accuracy of detecting the brachial -ankle pulse wave velocity (baPWV ) by ultrasonography technology through the comparative analysis of the results of brachial ankle pulse wave velocity detected by multi-method in the same group of subjects .Methods:Thirty cases of healthy people were enrolled .Three kinds of methods (①Joint using of Doppler probe and pulse wave sensor simultaneously .②Using Doppler probe only .③Using Colin arteriosclerosis detecting device) were applied to detect baPWV .Then the results were compared and analyzed .Results:The baPWV (brachial pulse wave-tibial Doppler) was (1135 .74 ± 246 .26) ,when the pulse wave sensor was placed in the brachial artery and the Doppler probe was placed in the posterior tibial artery simultaneously .The baPWV (Doppler) was (1048 .96 ± 117 .24) ,when the Doppler probe was placed in the brachial artery and the posterior tibial artery in two times respectively .The baPWV(arteri-osclerosis detecting device) was (1118 .20 ± 176 .42) ,which was detected by Colin arteriosclerosis detecting device .There were positive correlations and no statistical significance between the test result by arteriosclerosis detecting device and the test result when the ultrasonic Doppler probe was placed on the left posterior tibial artery while the pulse wave sensor was placed on the left brachial artery (r=0 .549 ,P<0 .01) .There were no correlations (r=0 .277 ,P>0 .05) and obviously statistical significance between baPWV(Doppler) and baPWV (arteriosclerosis detecting device) .Conclusions :Joint applying the ultrasonic probe and the pulse wave sensor provides a new method for the detection of pulse wave velocity .This method is with high accuracy and worth to be used in clinical area and to be further spread .Detecting pulse wave velocity by only using Doppler probe has more error rate .

关键词

超声检查/脉搏波传导速度/对比研究

Key words

Ultrasonography/Brachial-ankle pulse wave velocity/Comparative study

引用本文复制引用

任亚娟,肖沪生,徐芳,银浩强,高东雯,王奇..多方法检测肱-踝动脉脉搏波传导速度的比较研究[J].中国中西医结合影像学杂志,2014,(2):116-118,3.

基金项目

上海市教委科研课题(shzy020)。 ()

中国中西医结合影像学杂志

1672-0512

访问量0
|
下载量0
段落导航相关论文