Abstract
Experimental research on operating characteristics of floor heating combination household central air condi -tioning unit in different environmental conditions and different water supply temperature which to meet the low -tem-perature radiant floor heating was carried out.and the reliability of service under cold and high humidity condition is further more studied.The results show that household central air conditioning unit can work reliable under cold and high humidity condition , and the cop is 3.2 under nominal operating conditions as well as providing a basis for equipment selection in practical engineering design.关键词
户式地暖中央空调/低温地板辐射供暖/寒冷高湿Key words