浙江电力Issue(1):30-33,4.
1000 MW汽轮发电机组凝结水管道振动原因分析与处理
Cause Analysis and Treatment on Vibration of Condensate Pipe of 1 000 MW Steam Turbine Generating Units
王树帅 1唐璐2
作者信息
- 1. 神华国华浙江浙能发电有限公司,浙江 宁波 315612
- 2. 苏州热工研究院有限公司,江苏 苏州 215004
- 折叠
摘要
Abstract
The paper analyzes cause for excessive vibration of condensate pipe of 1 000 MW steam turbine generating units of Shenhua Guohua Ninghai Power Generating Co., Ltd., by reconstruction of valve core of main condensate regulating valve, restoration and reinforcement of hangers of condensate pipes, the vibration of condensate pipes is effectively solved and potential hazards in operation of condensate system are eliminated.关键词
凝结水管道/振动/阀芯/支吊架Key words
condensate pipe/vibration/valve core/hangers分类
能源科技引用本文复制引用
王树帅,唐璐..1000 MW汽轮发电机组凝结水管道振动原因分析与处理[J].浙江电力,2014,(1):30-33,4.