替代制冷剂空气源热泵热水器性能的理论与实验研究OA
Theoretical and Experimental Study on Performance of Air Source Heat Pump Water Heater with Alternative Refrigerants
在热泵热水器使用的典型工况下对R22、R427a、R134a的循环特性进行了理论分析,并在某机组上开展R22、R427a、R134a的直接充注对比实验,研究三种制冷剂的吸/排气压力及温度、压缩机功率、制热量、性能系数随环境温度变化的关系,得出了各特性参数的变化规律;实验表明,R427a与R22相比,制热量下降9%~10%,功率下降5%~6%,COP下降3%~4%,吸气和排气压力分别下降15%~20%、3%~5%,吸气温度上升1℃~3℃,排气温度下…查看全部>>
Theoretical analysis and experiments were carried out on the air resource heat pump water heater using R22, R427a and R134a under different operating conditions. The change law of suction and discharge pressure, suction and discharge temperature, compressor power, heat capacity and COP with the environment temperature were obtained. The research results show that, by using R427 to replace R22 in the heat pump, the heat capacity decreases by 9%~10%, COP decre…查看全部>>
周全;樊海彬;贾磊;夏玲;陈熙;李世锁
合肥通用机械研究院,安徽合肥 230031合肥通用机械研究院,安徽合肥 230031合肥通用机械研究院,安徽合肥 230031合肥通用机械研究院,安徽合肥 230031合肥通用机械研究院,安徽合肥 230031大连三洋压缩机有限公司,辽宁大连 116033
R427a空气源热泵热水器COP
R427aAir source heat pump water heaterCOP
《制冷技术》 2013 (4)
19-23,5
评论