| 注册
首页|期刊导航|兵工自动化|基于COM Express模块的安全开关机方案

基于COM Express模块的安全开关机方案

秦友伦 袁强 涂炯

兵工自动化Issue(5):69-71,3.
兵工自动化Issue(5):69-71,3.DOI:10.7690/bgzdh.2014.05.020

基于COM Express模块的安全开关机方案

A Safety Power on and Shutdown Solution Based on COM Express Module

秦友伦 1袁强 1涂炯1

作者信息

  • 1. 中国兵器工业第五八研究所特种电子技术部,四川 绵阳 621000
  • 折叠

摘要

Abstract

In order to solve the problem of system crash, damaging file system due to non-safety power on and shutdown in the special embedded computer system which supplied by non-ATX power, a safety power on and shutdown design was put forward based on COM Express module in a non-ATX power supply system. It controls PS_ON pin to turn on or turn off the power. This paper give block diagram of the safety switch unit and introduce the hardware design of the switch control unit, CPLD control unit. It uses VerilogHDL language to design the software. This solution has been successfully applied to a project. The results show that the method is effective and feasible. It can change physical switching function and ensure system safety shutdown.

关键词

嵌入式计算机/CPCI/COM Express模块/安全开关机

Key words

embedded computer/CPCI/COM Express module/safety power on and shutdown

分类

信息技术与安全科学

引用本文复制引用

秦友伦,袁强,涂炯..基于COM Express模块的安全开关机方案[J].兵工自动化,2014,(5):69-71,3.

兵工自动化

OACSTPCD

1006-1576

访问量0
|
下载量0
段落导航相关论文