爆破器材Issue(3):48-51,4.DOI:10.3969/j.issn.1001-8352.2014.03.011
用快速筛选仪研究发射药的热分解*
Study on the Thermal Decomposition of Propellant Using Rapid Screening Device
陈永康 1陈明华 2张力 3贾昊楠 1于毅成 1刘立2
作者信息
- 1. 军械工程学院 河北石家庄,050000
- 2. 军械技术研究所 河北石家庄,050000
- 3. 军械技术研究所 河北石家庄,050000
- 折叠
摘要
Abstract
Rapid screening device (RSD), a new calorimeter, was used to test the thermal decomposition progress of GATo-3 propellant and 8/1 propellant .The thermal decomposition characteristic data and kinetic parameters obtained from RSD curves show that the initial decomposition temperature of GATo-3 is about 150-168 ℃, and that of 8/1 is about 175-185℃.The kinetic parameters of 8/1 are E=238.30 kJ/mol and A=3.7 ×1017 s-1 , while those of GATo-3 are E=216.67 kJ/mol and A=2.1 ×1017 s-1.关键词
快速筛选仪/发射药/热分解/热分析动力学Key words
rapid screening device/8/1 propellant/GATo-3 propellant/propellant/thermal decomposition/thermal analysis kinetics分类
化学化工引用本文复制引用
陈永康,陈明华,张力,贾昊楠,于毅成,刘立..用快速筛选仪研究发射药的热分解*[J].爆破器材,2014,(3):48-51,4.