| 注册
首页|期刊导航|传感技术学报|液体流量标准装置中开式换向器测量误差模型研究∗

液体流量标准装置中开式换向器测量误差模型研究∗

马龙博 郑建英 赵建亮

传感技术学报Issue(4):515-520,6.
传感技术学报Issue(4):515-520,6.DOI:10.3969/j.issn.1004-1699.2015.04.011

液体流量标准装置中开式换向器测量误差模型研究∗

Research on the Flow Measurement Error Model of the Diverter in the Liquid Flow Calibration Facilities

马龙博 1郑建英 1赵建亮1

作者信息

  • 1. 浙江省计量科学研究院,杭州310000
  • 折叠

摘要

Abstract

To overcome the error calculation difficulties of the diverter in the liquid flow calibration facilities, the limitations had been analyzed in the uncertainty model of the diverter at present. Based on considering the diversion damper situation and the jet flow velocity profile,a measurement error model of the diverter was developed in which the different location of the damper in the mid-travel was considered. The measurement error brought by the diverter was calculated based on the new measurement error model. Calculated results show that, the establishment of the new measurement uncertainty model of divert about the diversion damper situation was reasonable and could meet the error calculation of the divert.

关键词

流量测量/换向器/误差模型/液体流量标准装置

Key words

flow measurement/diverter/uncertainty model/liquid flow calibration facilities