| 注册
首页|期刊导航|磁共振成像|非对比剂增强MR血管成像联合多反转空间标记脉冲技术在肺动脉成像的可行性研究

非对比剂增强MR血管成像联合多反转空间标记脉冲技术在肺动脉成像的可行性研究

孟晓岩 汤浩 王秋霞 李震 李晓娟 陈晓 胡军武 胡道予

磁共振成像Issue(5):343-347,5.
磁共振成像Issue(5):343-347,5.DOI:10.3969/j.issn.1674-8034.2014.05.006

非对比剂增强MR血管成像联合多反转空间标记脉冲技术在肺动脉成像的可行性研究

Non-contrast-enhanced MR angiography using spatial labeling with multiple inversion pulses sequence imaging in pulmonary artery:a feasibility study

孟晓岩 1汤浩 1王秋霞 1李震 1李晓娟 1陈晓 1胡军武 1胡道予1

作者信息

  • 1. 华中科技大学同济医学院附属同济医院放射科,武汉430030
  • 折叠

摘要

Abstract

Objective:The purpose of this study was to demonstrate the feasibility of a non-contrast-enhanced magnetic resonance angiography (MRA) sequence, Multiple Inversion Pulses Sequence (SLEEK), used in pulmonary artery, and to explore the optimum blood-suppression inversion time (BSP-TI) for good image quality. Materials and Methods: Fourteen healthy volunteers who had no contraindications to MRI and no recent health problems or surgeries were recruited in the study. All subjects were performed at a 1.5 T MRI system for assessing pulmonary artery. The ability to present four segments (①pulmonary trunk.②main right and left pulmonary arteries.③interlobar arteries.④ segmental arteries bilaterally) were evaluated independently by two radiologists using a four-point scale. Relative signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) also were determined. Results:Thirteen volunteers were successfully performed SLEEK MRA, only one volunteer failed because of irregular respiration. The subjective image quality was signiifcantly better with BSP-TI 700 ms and 900 ms than with 500 ms, 1100 ms and 1300 ms (P<0.05). The CNR and relative SNR of pulmonary artery were significantly better with BSP-TI 700 ms than with 500 ms (P<0.05), though showed no signiifcantly better than with 900 ms, 1100 ms and 1300 ms (P>0.05), taking into the pulmonary venous contamination consideration (1100 ms 5/13, 1300ms 9/13), the image quality with BSP-TI 700 ms for pulmonary artery was signiifcantly better than with others. Conclusions:Performing non-contrast-enhanced MRA with SLEEK sequence can achieve clear vessel delineation both in central and peripheral pulmonary arteries with the BSP-TI of 700 ms.

关键词

肺动脉/磁共振血管造影术

Key words

pulmonary artery/Magnetic resonance angiography

分类

医药卫生

引用本文复制引用

孟晓岩,汤浩,王秋霞,李震,李晓娟,陈晓,胡军武,胡道予..非对比剂增强MR血管成像联合多反转空间标记脉冲技术在肺动脉成像的可行性研究[J].磁共振成像,2014,(5):343-347,5.

基金项目

国家基金面上项目(编号81371524);湖北省自然科学基金(编号2013CKB018) (编号81371524)

磁共振成像

OACSCDCSTPCD

1674-8034

访问量0
|
下载量0
段落导航相关论文