Abstract

The fire facilities, such as:alarm control, automatic detection and automatic sprinkler system, of which the resear-ch on the automatic pre-action sprinkler has made great achi-evements. Pre-action sprinkler system has advantages of tim-ely alarm, sensitive action and less water loss, so it is suitable for al kinds of data center room. This paper mainly discussed the application of fire pre-action sprinkler system in the data room.

关键词

消防/预作用喷淋系统/数据机房

Key words

fire prevention/pre-action sprinkler system/data room