电测与仪表Issue(7):24-29,6.
基于改进扰动功率法的电压暂降源定位
Voltage sag source location based on the improved disturbance power method
史丽萍 1于婷 1罗朋 1冯学俊1
作者信息
- 1. 中国矿业大学信息与电气工程学院,江苏徐州221008
- 折叠
摘要
Abstract
In the face of power quality problems caused by voltage sag , this paper proposes an improved disturbance power method combined with the common type of fault in power system .It redefines the disturbance power by taking the disturbance voltage multiplied with the disturbance current , according to the superposition principle of linear cir-cuit, fault network can be equivalent to the normal plus the disturbance component , and then it uses the polarity of transient disturbance power or half-cycle average to locate the voltage sag source .Finally through simulation by Matlab model, this approach proves to be accurate in voltage sag location .关键词
电能质量/电压暂降源定位/扰动功率/MatlabKey words
power quality/voltage sag source location/disturbance power/Matlab分类
信息技术与安全科学引用本文复制引用
史丽萍,于婷,罗朋,冯学俊..基于改进扰动功率法的电压暂降源定位[J].电测与仪表,2015,(7):24-29,6.