Abstract

Power fluctuation caused by irradiance changes , inverter cut-in and cut-off may cause flicker at the grid-connected point .The connection between the flicker and grid short-circuit capacity , grid impedance angle and power change amount is analyzed .And the flicker is tested on a 500 kW photovoltaic ( PV ) inverter at different load and switch operation .Based on the virtual gird model and the flicker meter model developed on Matlab /Simulink platform , the flicker results are tested and analyzed under these operation conditions .

关键词

并网光伏逆变器/闪变/虚拟电网/闪变测试仪

Key words

grid-connected PV inverters/flicker/virtual grid/flicker meter