电力系统自动化Issue(8):155-158,4.DOI:10.7500/AEPS20140404008
基于电力调度数据网双平面的主站控制多机多链路采集方案
A Scheme for Multi-machine and Multi-link Acquisition of Control Center Based on Electric Power Dispatching Data Network Dual Plane
叶飞 1金鑫 1朴林 2肖小刚3
作者信息
- 1. 南瑞集团公司 国网电力科学研究院 北京,北京市 100192
- 2. 国家电力调度控制中心,北京市 100031
- 3. 国家电网华中电力调控分中心,湖北省武汉市 430077
- 折叠
摘要
Abstract
To enhance the stability of the data acquisition system of power grid dispatching system,a method of data acquisition with multi-machine and multi-link as the main control center is proposed based on the dispatching data network dual plane technology of State Grid Corporation and following the technology standard for data acquisition and exchange for smart grid technical support systems.The method uses the multi-line in load balancing,multi-machine in parallel running,multi-link in hot standby and multi-link data processing technology to improve the stability and reliability of data acquisition,solve the accuracy problem of the data caused by a single node failure to meet the needs of grid dispatching operation and control.The data acquisition system based on this method is in operation in several control centers.关键词
智能电网/数据采集与交换/电力调度数据网/双平面/采集通道/链路管理/并列运行Key words
smart grid/data acquisition and exchange/state grid data network/dual network plane/data acquisition channel/link management/parallel running引用本文复制引用
叶飞,金鑫,朴林,肖小刚..基于电力调度数据网双平面的主站控制多机多链路采集方案[J].电力系统自动化,2015,(8):155-158,4.