地震地磁观测与研究Issue(3):192-197,6.DOI:10.3969/j.issn.1003-3246.2014.03/04.032
永年地震台水管加速N倾异常分析
Analysis on accelerated northward tilt anomaly of N component of water tube tiltmeter at Yongnian Seismic Station
摘要
Abstract
There is accelerated northward anomaly of water tube tiltmeter NS component at Yongnian Seismic Station from September 2012.We survey the cavern environment,instrument sys-tem,environmental disturbance,and power supply system,calculating the theoretical values of load influences to crustal tilt observation by three-dimensional concentration load model, while the load influences include quarry and soil excavating.We primarily judge the anomaly caused by environmental disturbance through qualitative analysis and quantitative calcula-tion.关键词
倾斜/水管倾斜仪/荷载/环境干扰Key words
tilt/water tube tiltmeter/load/environmental disturbance引用本文复制引用
马栋,陈建国,张双凤,袁国旭,张冀东..永年地震台水管加速N倾异常分析[J].地震地磁观测与研究,2014,(3):192-197,6.基金项目