电子器件Issue(3):556-559,4.DOI:10.3969/j.issn.1005-9490.2014.03.038
电源线尖峰信号传导敏感度问题分析及解决
Analysis and Resolving of Problem about Power Supply Cable Spike Conducted Susceptivity
杨志丹 1王岩 2贺永喜2
作者信息
- 1. 海军代表室,北京10076
- 2. 北京航天发射技术研究所,北京100076
- 折叠
摘要
Abstract
In order to solve power supply cable spike conducted susceptivity ( cs06 ) that photoelectric detection equipment was in electromagnetic compatibility test, the photoelectric detection equipment was done much work including work principle analysis,the failure tree analysis and test certification. The result proved that it was the degradation of matching performance that the linear power supply and the power supply filter was sensitive to cs06 was the major cause. The equipment anti-interference capability was improved by adding two differential-mode ca-pacitances and two differential-mode inductances in power module. The method was available.关键词
电磁兼容/故障分析/电源线尖峰信号传导敏感度(CS106)/差摸/干扰Key words
electromagnetic compatibility/the failure analysis/power supply cable spike conducted susceptivity ( cs106 )/differential-mode/interference分类
信息技术与安全科学引用本文复制引用
杨志丹,王岩,贺永喜..电源线尖峰信号传导敏感度问题分析及解决[J].电子器件,2014,(3):556-559,4.