A vanadium redox flow batteries system was modelling. Through theoretical analysis and research on the all vanadium redox flow batteries system under different pipe diameter and velocity of pump loss,the pump depletion of the law is concluded. Using the Fluent software simulate half cell electrolyte distribution under different flow rate,the performances of all vanadium redox flow batteries are affected by different charging current and velocity. Results show that according to the loss of vanadium battery structure optimization control pump and the electrolyte flow rate,it is very important to improve the efficiency of vanadium battery energy storage system and the battery system stability. In the large scale energy storage technology,the pump damage and the influence of flow rate are more apparent.关键词
钒氧化还原液流电池/泵功率/流量/电池性能Key words
vanadium redox flow batteries/pump power/flow rate/battery performance分类