辽宁石油化工大学学报Issue(2):46-49,4.DOI:10.3696/j.issn.1672-6952.2015.02.010
脱水沉降罐经济保温层厚度的逆向优化计算
Determine the Economic Thickness of the Insulation Layer on the Dewatering Settlement Tank
关丽 1刘德俊 1周志强1
作者信息
- 1. 辽宁石油化工大学石油天然气工程学院,辽宁抚顺 113001
- 折叠
摘要
Abstract
In the case of determining the optimum dehydration temperature in the settling tank,the settling tank outlet temperature was obtained by a reverse operation based on the analysis of sedimentation tank of energy balance.One optimal mathematical model,which used fuel oil heating cost and additional insulation layers with different thickness of the total investment cost at least,was established and solved by C+ + program.According to the optimized calculation,the optimal insulation thickness was about 68mm and the lowest total cost was about 1.456 3 million yuan.关键词
沉降罐/保温层厚度/优化计算/数学模型/脱水温度Key words
Sedimentation tank/Insulation layer thickness/Optimized calculation/Mathematical model/Dehydration temperature分类
能源科技引用本文复制引用
关丽,刘德俊,周志强..脱水沉降罐经济保温层厚度的逆向优化计算[J].辽宁石油化工大学学报,2015,(2):46-49,4.