| 注册
首页|期刊导航|广东电力|消弧线圈并联小电阻的灵活接地方式

消弧线圈并联小电阻的灵活接地方式

黄志方 魏立新 李刚

广东电力Issue(6):64-67,4.
广东电力Issue(6):64-67,4.DOI:10.3969/j.issn.1007-290X.2014.06.014

消弧线圈并联小电阻的灵活接地方式

Flexible Grounding via Arc-suppression Coil and Low Resistance in Parallel

黄志方 1魏立新 1李刚1

作者信息

  • 1. 思源电气股份有限公司,上海201108
  • 折叠

摘要

Abstract

Aiming at defects of grounding mode of neutral point via arc-suppression coil being not rapid and correct enough for line selection for permanent fault while unable to distinguish fault types via low resistance,this paper proposes a flexible grounding mode via arc-suppression coil and low resistance in parallel by combining advantages such as high power supply re-liability of arc-suppression coil grounding and rapid switch-off for fault of low resistance grounding.The basic idea of this grounding mode is to input arc-suppression coil at the moment of normal running and instant grounding fault occurring while to switch low resistance when permanent fault occurs in order to realize flexible transform of neutral grounding mode.This paper introduces composition and working principle of the flexible grounding device and parameter selection for low resist-ance.By two practical cases,it proves that this flexible grounding mode is able to reduce line trip rate and improve power supply reliability which is suitable for city power distribution network mixing cable lines with overhead lines.

关键词

中性点接地方式/消弧线圈/小电阻/永久性故障/瞬时故障

Key words

neutral grounding mode/arc-suppression coil/low resistance/permanent fault/instant fault

分类

信息技术与安全科学

引用本文复制引用

黄志方,魏立新,李刚..消弧线圈并联小电阻的灵活接地方式[J].广东电力,2014,(6):64-67,4.

广东电力

OACSTPCD

1007-290X

访问量0
|
下载量0
段落导航相关论文