广东电力Issue(4):98-105,8.DOI:10.3969/j.issn.1007-290X.2015.04.020
10 kV 配电网感应雷过电压的计算及影响因素分析
Analysis on Calculation and Influencing Factors on Lightning Induced Overvoltage of 10 kV Power Distribution Network
摘要
Abstract
In order to study influencing factors on lightning induced overvoltage of 10 kV power distribution network,based on electromagnetic field principle in the stage of lead discharge to lightning return,this paper confirms an optimal calcula-tion model by studying several mathematical models for working out lightning induced overvoltage without considering influ-ence of environmental factors such as temperature,humidity and terrain. It analyzes influencing factors on lightning induces overvoltage by using MATLAB simulation software and obtains relationship between various influencing factors and lightning induced overvoltage. The result indicates that the lightning current amplitude is larger,the line height is higher and the lightning strike distance is closer,the overvoltage amplitude and gradient of wave head is larger.关键词
感应雷过电压/先导发展过程/回击过程/影响因素Key words
lightning induced overvoltage/lead development process/return process/influencing factor分类
信息技术与安全科学引用本文复制引用
刘峻岐,王小霖,张弦,刘刚..10 kV 配电网感应雷过电压的计算及影响因素分析[J].广东电力,2015,(4):98-105,8.基金项目
广东省科技计划资助项目(2013B010405002) (2013B010405002)