首页|期刊导航|电力系统保护与控制|基于模糊控制的电池储能系统辅助AGC调频方法

基于模糊控制的电池储能系统辅助AGC调频方法OA北大核心CSCDCSTPCD

Battery energy storage aid automatic generation control for load frequency control based on fuzzy control

中文摘要英文摘要

针对 AGC 控制中火电机组响应时滞长、机组爬坡速率低的问题,提出了一种基于模糊控制策略的电池储能系统(Battery Energy Storage System,BESS)辅助AGC调频方法。该方法以区域控制偏差(Area Control Error,ACE)及其变化率作为模糊控制器的输入量,BESS 的参考功率变化量作为输出量,根据系统的运行状态调节 BESS 输出功率,辅助火电机组改善电网的动态调频性能。基于Matlab/Simulink平…查看全部>>

As the thermal power units often require a long time to response to load disturbance and have low unit ramp rate, a method of battery energy storage system assisted automatic generation control based on fuzzy control strategy is proposed. This fuzzy controller uses Area Control Error (ACE) and its rate of change as inputs and the reference power variation as output. BESS output power is adjusted according to the system's operating status, assisting to improv…查看全部>>

丁冬;刘宗歧;杨水丽;吴小刚;李婷婷

华北电力大学电气与电子工程学院,北京 102206华北电力大学电气与电子工程学院,北京 102206中国电力科学研究院,北京 100192华北电力大学电气与电子工程学院,北京 102206华能北京热电有限责任公司,北京 100023

信息技术与安全科学

电池储能系统(BESS)AGC控制模糊控制区域控制偏差(ACE)两区系统模型

battery energy storage system (BESS)AGC controlfuzzy controlarea control error (ACE)two-area system model

《电力系统保护与控制》 2015 (8)

81-87,7

国家电网公司科技项目资助(DG71-14-032, DG71-13-031)