| 注册
首页|期刊导航|计量学报|基于 TEM 小室的探头校准系统不确定度评定

基于 TEM 小室的探头校准系统不确定度评定

刘潇 李渤 谢鸣

计量学报Issue(3):318-323,6.
计量学报Issue(3):318-323,6.DOI:10.3969/j.issn.1000-1158.2015.03.20

基于 TEM 小室的探头校准系统不确定度评定

The Uncertainty Estimation for the Probe Calibration Results Employing a TEM Cell

刘潇 1李渤 1谢鸣1

作者信息

  • 1. 中国计量科学研究院,北京 100029
  • 折叠

摘要

Abstract

The TEM cell is used widely as an electromagnetic field generator,and by employing it,a probe calibration system can be set up to calibrate the radio frequency electromagnetic field probe. A probe calibration system working at 300 kHz ~ 100 MHz is analyzed,and the measurement result uncertainty is presented for a magnetic field probe at five different frequencies in that range. The analysis takes into account the effect of the wave impedance inside the TEM cell,and that of the interaction between the probe and the standard field etc,which can be a useful guide to analyse the electromagnetic field probe calibration process.

关键词

计量学/TEM小室/电磁场探头/校准系统/测量不确定度

Key words

Metrology/TEM cell/Electromagnetic field probe/Calibration system/Uncertainty