The simultaneous determination of arsenic and selenium in water by atomic fluorescence spectrometry method may be interfered by each other. A lot of experiments through concentration of potassium borohydride and hydrochloric acid were made in order to find the best simultaneous determination condition of arsenic and selenium,and the accuracy and precision of datum were analyzed. The results show that when concentration of potassium borohydride is 3.0% and concentration of hydrochloric acid is 10% is the optimum condition,the method is simple and accurate for the simultaneous determination of arsenic and selenium in water.关键词
原子荧光法/砷/硒/同时测定/最佳条件Key words
atomic fluorescence spectrometry/arsenic/selenium/simultaneous determination/optimum condition分类
建筑与水利引用本文复制引用