The simultaneous determination of trace F -,Cl -,SO2 -4 and NO 3 in hemodialysis water by chromatography was introduced-in this paper. Sample volume,eluent concentration and checker current were optimized by operation. The detection limits of F -,Cl, SO2 --4 and NO 3 are 0. 012,0. 014,0. 074 and 0. 016 mg/ L,respectively. The recovery rates are in the range of 90% and 110% . The environmental standard (204715)was tested six times. The anion concentration is in range of twice as large as recommended value uncertainty. Relative standard deviation is less than 2% . This method has the advantages of rapidity,high sensitivity and accuracy, which can be used for determining F -,Cl -,SO2 -4 and NO 3 in hemodialysis water simultaneously.关键词
离子色谱/透析用水/电导检测/阴离子Key words
ion chromatography/hemodialysis water/conductivity detection/anion分类
建筑与水利引用本文复制引用
张飞,李华玲,韩翠杰..离子色谱法同时测定透析用水中痕量氟、氯、硫酸根和硝酸根[J].净水技术,2015,(3):26-29,4.基金项目
国家重大科学仪器开发专项应用方法开发项目 ()