| 注册
首页|期刊导航|检验医学与临床|UF-1000i尿沉渣分析仪与显微镜检测尿液小圆上皮细胞对比分析及参考值建立

UF-1000i尿沉渣分析仪与显微镜检测尿液小圆上皮细胞对比分析及参考值建立

阳建 余赛红 文艳 刘爱胜

检验医学与临床Issue(12):1642-1643,2.
检验医学与临床Issue(12):1642-1643,2.DOI:10.3969/j.issn.1672-9455.2014.12.022

UF-1000i尿沉渣分析仪与显微镜检测尿液小圆上皮细胞对比分析及参考值建立

UF-1000i urine sediment analyzer and microscope detection small round epithelial cells results contrast analysis and es-tablish the reference range

阳建 1余赛红 1文艳 2刘爱胜3

作者信息

  • 1. 广东省深圳市宝安区沙井人民医院检验科 518104
  • 2. 广东省深圳市光明新区人民医院ICU 518106
  • 3. 广东省深圳市龙华新区人民医院检验科 518109
  • 折叠

摘要

Abstract

Objective U F-1000i urine sediment analyzer and microscope detection small round epithelial cells results contrast analysis and the reference range ,provide a more accurate and reliable experimental data for clinical and scientific diagnostic reference range .Methods 165 cases of urine specimen of midway through the morning urine were collected in urology and small and medium-sized round epithelial cells from those specimen were detected by UF-1000i or under microscope respectively .While 1 296 cases randomly collected health check-up crowd midway through the morning urine microscope detection small round epithelial cells ,establish healthy crowd reference range of clinical diagnosis of urinary small round epithelial cells .Results With microscope examination as the gold stand-ard ,white blood cells in the urine under normal circumstances ,UF-1000i urine sediment to test urine small round epi-thelial cells slightly higher than the microscopy ,there was no statistically significant difference between the results (t=1 .24 ,P>0 .05) ,and white blood cells in urine increased cases ,UF-1000i test results than microscopy ,the results have significant difference between statistical significance (t= 6 .92 ,P< 0 .01) .Healthy crowd midway through the morning urine small round epithelial cells biology reference range ,there was no statistically significant difference be-tween age and gender(t=1 .06 ,P>1 .06) ,the female results slightly higher than the male .Conclusion Urine leuco-cyte heighten ,UF-1000i urinary sediment analyzer to detect urinary small round epithelial cells has bigger difference between test results and microscope ,the leukocyte results abnormal urinary epithelial cells of small round epithelial cells inspections with microscope ,in order to improve the accuracy of the results .Establish biological reference range , provide more valuable for clinical diagnosis ,treatment of diagnosis .

关键词

UF-1000i尿沉渣分析仪/显微镜/小圆上皮细胞/对比分析/参考区间

Key words

UF-1000i urine sediment analyzer/microscope/small round epithelial cells/comparison and analysis/reference range

引用本文复制引用

阳建,余赛红,文艳,刘爱胜..UF-1000i尿沉渣分析仪与显微镜检测尿液小圆上皮细胞对比分析及参考值建立[J].检验医学与临床,2014,(12):1642-1643,2.

检验医学与临床

OACSTPCD

1672-9455

访问量0
|
下载量0
段落导航相关论文