| 注册
首页|期刊导航|检验医学与临床|标本血量不足对凝血酶原时间及活化部分凝血活酶时间检测结果的影响

标本血量不足对凝血酶原时间及活化部分凝血活酶时间检测结果的影响

徐菡 邸平 夏全成 马骏龙 王成彬

检验医学与临床Issue(16):2201-2202,2.
检验医学与临床Issue(16):2201-2202,2.DOI:10.3969/j.issn.1672-9455.2014.16.004

标本血量不足对凝血酶原时间及活化部分凝血活酶时间检测结果的影响

Influence of insufficient blood volume on the detection results of PT,APTT

徐菡 1邸平 1夏全成 1马骏龙 1王成彬1

作者信息

  • 1. 解放军总医院临床检验科,北京 100853
  • 折叠

摘要

Abstract

Objective To demonstrate the influence of blood samples volume on the prothrombin time ( PT ) and activated partial thromboplastin time (APTT) results .Methods Fifty eight cases were chosen whose HCT was 20% -55% .After centrifugation ,there was no hemolysis ,lipemia or icterus .According to the proportion of blood and anticoagulant ,samples were divided into 2 groups ,8∶ 1 group and 7∶ 1 group .Then re-extracted sufficient blood(2 .7 mL) for each control group(9 ∶ 1) respectively ,blood samples of these 4 groups were detected PT , APTT .Results The PT results of 8∶ 1 group and the control group was not statistically different ,and the PT re-sults of 7∶1 group and the control group was statistically different .The APTT results of 8∶1 ,and 7∶1 were statis-tically different with the control group .Conclusion The detection of coagulation project PT and APTT′s results were affected by the proportion of blood and anticoagulant .

关键词

凝血酶原时间/活化部分凝血活酶时间/标本采集量

Key words

prothrombin time/activated partial thromboplastin time/specimen collection volume

引用本文复制引用

徐菡,邸平,夏全成,马骏龙,王成彬..标本血量不足对凝血酶原时间及活化部分凝血活酶时间检测结果的影响[J].检验医学与临床,2014,(16):2201-2202,2.

基金项目

国家科技支撑计划项目(2013BAI17B05);全军医学科研十二五计划项目(AWS11Z005-4)。 ()