流体机械Issue(7):51-54,4.DOI:10.3969/j.issn.1005-0329.07.012
延迟焦化辐射进料泵节能改造
Energy Saving Retrofit Project for Heater Charge Pump in Delayed Coking Unit
陶铁梅1
作者信息
- 1. 青岛思远化工有限公司,山东青岛 266500
- 折叠
摘要
Abstract
Taking the feed pump in delayed coking unit of Refining Branch as the example ,the influencing factors of the energy consumption were analyzed among three solutions including impeller trimming ,impeller removing ,and frequency controlling of mo-tor speed,the corresponding retrofit solution was proposed .Compared with the on-site operational state ,the combination of impeller trimming and impeller removing solution makes an obvious energy saving effect .关键词
节能改造/叶轮切割/变频调速Key words
energy saving retrofit/impeller trimming/frequency controlling of motor speed分类
机械制造引用本文复制引用