| 注册
首页|期刊导航|国际眼科杂志|Q值引导LASEK治疗正性 Q值近视及散光的视觉质量研究

Q值引导LASEK治疗正性 Q值近视及散光的视觉质量研究

王佼佼 张立军 张繁友 韩茜 牟亚男

国际眼科杂志Issue(8):1478-1480,3.
国际眼科杂志Issue(8):1478-1480,3.DOI:10.3980/j.issn.1672-5123.2014.08.30

Q值引导LASEK治疗正性 Q值近视及散光的视觉质量研究

Visual quality of Q-factor guided LASEK for myopia and astigmatism with positive Q-factor

王佼佼 1张立军 1张繁友 1韩茜 1牟亚男1

作者信息

  • 1. 116011 中国辽宁省大连市第三人民医院视光学中心
  • 折叠

摘要

Abstract

AIM: To explore the long-term efficacy of Q-factor guided laser epithelial keratomleusis ( LASEK ) for myopia and astigmatism with positive Q-factor. <br> METHODS: There were 158 eyes which were myopia and astigmatism with positive Q- factor taken in two groups randomly: 86 eyes accepted Q - factor guided LASEK as observation group and 72 eyes accepted routine LASEK as control group. The difference between the two groups about all data was similar. The uncorrected visual acuity ( UCVA ) and the best corrected visual acuity ( BCVA ) as well as diopter, ocular tension, corneal topography, Keratometry value K, aspherical factor Q, Higher-order aberrations ( HOA ) , corneal thickness by ultrasound and, contrast sensitivity ( CS ) , Haze were examined and compared before and after surgery. All the cased were followed up for 14d, 1, 3, 6, 12mo. And there were no statistical difference among the data before surgery. <br> RESULTS: After 12mo there were no statistical difference between the two groups about UCVA and BCVA. But the safety index of observation group was 1.10, that of control group was 1. 07. The validity index of observation group was 1. 06, that of control group was 0.99. The HOA of observation group was 0. 45±0. 17μm,&nbsp;and that of control group was 0. 72±0.25μm, there was statistically significant difference (t=-8. 193,P=0. 000). Q factor of observation group was 0. 41±0. 17, that of control group was 0. 77±0. 22, there was significant difference (t=11. 377,P = 0. 028). The contrast sensitivity of 3mo post surgery of patients in the observation group returned to the level of before surgery. But in the control group the contrast sensitivity of the patients did not returned until 6mo. <br> CONCLUSION:Q-factor guided LASEK for myopia and astigmatism with positive Q-factor is stable, safe and effective. The operation allow for reducing the high order aberrations, maintaining the most asphericity of cornea, saving more in corneal tissue, which cause faster recovery of contrast sensitivity, less haze and better visual quality.

关键词

正性非球面因子/近视/散光/角膜磨镶术

Key words

aspherical factor Q/myopia/astigmatism/keratomileusis

引用本文复制引用

王佼佼,张立军,张繁友,韩茜,牟亚男..Q值引导LASEK治疗正性 Q值近视及散光的视觉质量研究[J].国际眼科杂志,2014,(8):1478-1480,3.

基金项目

中国辽宁省大连市科技计划资助项目(No.2011E15SF115) (No.2011E15SF115)

国际眼科杂志

OACSTPCD

1672-5123

访问量0
|
下载量0
段落导航相关论文