Abstract

Abstract•AlM:To discuss the feasibility of using the visual quality analyzer KR - 1W to guide the relatively personalized aspheric intraocular lens ( lOL ) implants to make the whole eye spherical aberration close to 0. 1μm.•METHODS: ln this prospective case series study, the corneal spherical aberration with 6mm aperture of 73 patients (100 eyes) was measured with KR-1W Visual Function Analyzer 1d before surgery. For the sake of the whole postoperative spherical aberration were close to 0. 1μm, 9 cases ( 16 eyes ) with corneal spherical aberration <0. 15μm were implanted Sofport Advanced Optic lOL, named AO group;45 cases ( 57 eyes ) with corneal spherical aberration 0. 25~0. 3μm were implanted AcrySof lQ lOL, named lQ group;19 cases (27 eyes) with corneal spherical aberration > 0. 35μm were implanted Tecnis ZA9003 lOL, named Tecnis group. Aspherical lOL was implanted after phacoemulsification through a cornea 2. 75mm incision without suture. Uncorrected visual acuity, beat corrected visual acuity, spherical aberration of the whole eye and jnternal optics (mainly lOL) at 6mm pupil diameter were examined at 3mo postoperatively. The relevant data were analyzed using t-test and variance analysis.•RESULTS: The whole ocular spherical aberration at 6mm pupil diameter in all postoperative were 0. 084 ± 0. 032μm;in Tecnis group, the data were 0. 091 ± 0. 021μm;in AO group, the data were 0. 0814-0. 013μm;lQ group were0. 093 ± 0. 042μm. There was no significantly different between the predicted value and actual value of ocular spherical aberration at 6 mm pupil diameter in all postoperative ( t = 1. 932, P = 0. 061 ) and in the three groups. The difference value in the predicted values of the preoperative spherical aberrations of the whole eye and the actual values after surgery was 0. 013±0. 041μm; there was no statistically significant difference ( F=2. 537, P=0. 091 ) . Respectively compared the uncorrected visual acuity and besta corrected visual acuity among three groups of postoperative, no significant difference were found (F=0. 897, P=0. 421;F=1. 423, P=0. 097).•CONCLUSlON: Personality selection of aspheric lOL based on preoperative corneal spherical aberration of patients is feasible and produces satisfactory target postoperative total spherical aberration.

关键词

KR-1 W/非球面人工晶状体/个性化植入

Key words

•KEYWORDS:KR-1W/aspheric intraocular lens/personalized implant

引用本文复制引用

王晓莉,李倩,唐晓蕾,吕迎春,郭丽..视觉质量分析仪 KR-1 W指导非球面 lOL个性化植入的可行性评估[J].国际眼科杂志,2015,(1):43-45,3.

国际眼科杂志

OACSTPCD

1672-5123

访问量0
|
下载量0
段落导航相关论文