Objective To explore the effect of 3 M liquid dressing on the prevention of ECG electrodes-induced skin injury for aged patients. Methods Sixty aged patients with ECG monitoring were included for a self-control study. Conventional side and observation side were distinguished based on paste position of electrodes and 3 M liquid dressing was applied in observation side. The electrode was replaced with an interval of 48h then the incidence of contact dermatitis and the pain when removing the electrode were compared in both groups. Results There were lower incidence of contact dermatitis and less pain when removing the electrode in observation side, which indicated statistical significance (P<0.05). Conclusion 3 M liquid dressing is effective for the prevention of contact dermatitis meanwhile patients experience less pain when removing the electrode, which is worth to be promoted clinically.关键词