内蒙古电力技术Issue(3):94-96,100,4.DOI:10.3969/j.issn.1008-6218.2014.03.016
循环水泵出口蝶阀液压控制系统故障分析与处理
Fault Analysis and Treatment of Hydraulic Control System on Circulating Pump Outlet Valve
高翔1
作者信息
- 1. 内蒙古京能电力检修有限公司,内蒙古 乌兰察布 012000
- 折叠
摘要
Abstract
For the common problems of LJ040224 hydraulic control system in circulating water pump outlet valves on No.7 and No.8 units in Datong Second Power Plant, such as aging equipment, pipe welding adverse, circuit component failure, respectively carried on the reason analysis and gave the solutions. LJ040224 hydraulic systems of circulating water pump were improved further by adding the accumulator, replacement of oil pumps and other measures, improved the security of the units and equipments.关键词
循环水泵液压控制系统/液压蝶阀/工作油泵/蓄能器Key words
circulating pump hydraulic system/hydraulic valve/oil pump/accumulator分类
能源科技引用本文复制引用