内蒙古电力技术Issue(3):97-100,4.DOI:10.3969/j.issn.1008-6218.2014.03.021
发电机集电环及碳刷烧损事故原因分析及现场处理
Cause Analysis of Generator Collector Ring and Carbon Brush Burning
郭颀 1郭志敏2
作者信息
- 1. 北方联合电力有限责任公司呼和浩特热电厂,呼和浩特 010020
- 2. 北方联合电力有限责任公司达拉特发电厂,内蒙古 鄂尔多斯 014300
- 折叠
摘要
Abstract
One 330 MW steam turbine generator of a power plant was damaged in Inner Mongolia, not only caused generator slip ring and carbon brush burning, but also the generator shaft damaged. Analysis the cause of the failure was due to the insulating sleeve quality defects, tripping out of glass cloth by high speed rotating rotor fan was broken and went into the slip ring and carbon brush, eventually led to the fault. Through the scene processing, repaired the generator shaft, collector ring and carbon brush. At present, the generator is running in good condition. Through the fault handling, it is suggested that there are power plants of the same kind of generator, reinforce the generator slip ring insulation sleeve.关键词
发电机/大轴/集电环/碳刷/绝缘套筒/玻璃丝布Key words
generator/shaft/collector ring/carbon brush/insulating sleeve/glass fiber cloth分类
信息技术与安全科学引用本文复制引用
郭颀,郭志敏..发电机集电环及碳刷烧损事故原因分析及现场处理[J].内蒙古电力技术,2014,(3):97-100,4.