内蒙古电力技术Issue(1):39-43,5.DOI:10.3969/j.issn.1008-6218.2015.01.017
锅炉高温受热面管氧化皮检测分析
Inspection and Analysis of Boiler Oxide Skin High-temperature Heating Surface
张俊伟1
作者信息
- 1. 内蒙古京能康巴什热电有限公司,内蒙古 鄂尔多斯 017010
- 折叠
摘要
Abstract
The result of a test to oxide skin in high-temperature tube of 350 MW supercritical boiler showed that the weight of oxide skin filled in 4 FHRs topped 20 g, and the thickness was up to 10 mm. Analysis was regarded that the phenomenon was caused by a large thermal deviation between the screens of the FHR in the runtime. And the oxide skin kept peeling resulted from the rate of the overquick speed of inner furnace wall temperature changes. To the problems above, propose to prevent the blockage of the pipeline caused by oxide skin peeling and over temperature, by means of controlling the boiler operating temperature strictly, strengthening the monitoring and adjustment to the thermal deviation of high-temperature surface, reducing the boiler start-stop time, which can provide reference to the similar solvement.关键词
氧化皮/高温受热面/热偏差/末级过热器/末级再热器Key words
oxide skin/high-temperature heating surface/thermal deviation/FSH/FRH分类
信息技术与安全科学引用本文复制引用
张俊伟..锅炉高温受热面管氧化皮检测分析[J].内蒙古电力技术,2015,(1):39-43,5.