| 注册
首页|期刊导航|内蒙古电力技术|云计算数据中心制冷方案分析

云计算数据中心制冷方案分析

葛银海 孙立德 王志明

内蒙古电力技术2015,Vol.33Issue(3):10-13,4.
内蒙古电力技术2015,Vol.33Issue(3):10-13,4.DOI:10.3969/j.issn.1008-6218.2015.03.010

云计算数据中心制冷方案分析

Refrigeration Scheme Analysis of Cloud Computing Data Center

葛银海 1孙立德 1王志明1

作者信息

  • 1. 内蒙古京能盛乐热电有限公司,呼和浩特 011518
  • 折叠

摘要

Abstract

Hohhot Shengle modern service industry agglomeration area of cloud computing data center by the unit of cold hot electricity trigeneration shengle thermal power plant to provide cold source, the refrigeration station issue load for 5000 t of the cold. With analysis and comparison, choose libr absorption chiller, and proposed four kinds of refrigeration technology solutions. Through the analysis, using hot water lithium bromide absorption refrigeration, although the initial investment and operation cost is larger, but the scheme can realize the step utilization of energy, the thermal efficiency can reach above 80%. Low power units can be made up in the summer heat load, balanced thermal power plant steam load of winter and summer. To improve the safety and reliability of cloud computing data center, reduce equipment maintenance workload and cost. So the data center using hot water absorption refrigeration.

关键词

云计算数据中心/冷热电三联供机组/热水吸收式制冷/溴化锂吸收式制冷机/冷负荷

Key words

cloud computing data center/cold and hot electricity trigeneration unit/hot water absorption refrigerating/lithium bromide absorption refrigerating machine/cooling load

分类

信息技术与安全科学

引用本文复制引用

葛银海,孙立德,王志明..云计算数据中心制冷方案分析[J].内蒙古电力技术,2015,33(3):10-13,4.

内蒙古电力技术

1008-6218

访问量0
|
下载量0