Combining with the characteristic of buried cable in urban power distribution network such as multiple joint, large amount and wide distribution, based on CAN-BUS distribution measurement and GSM/GPRS wireless communication designs an on-line monitoring system for temperature rise of power cable joint in urban power distribution network. Analyzes the integrated design schemes, logic construction frame composition, distributed collection system and the function of network dynamic monitoring platform of upper monitor management station. The result shows that the system can solve the problems of higher failure rate and inconvenient monitoring of joint temperature rise in the operation of buried power cable,and improve reliable operation level of equipments.关键词