| 注册
首页|期刊导航|宁夏电力|超临界四角切圆锅炉冷态空气动力场试验研究

超临界四角切圆锅炉冷态空气动力场试验研究

刘建华 马国伟 白杨

宁夏电力Issue(6):61-67,7.
宁夏电力Issue(6):61-67,7.DOI:10.3969/j.issn.1672-3643.2014.06.013

超临界四角切圆锅炉冷态空气动力场试验研究

Test research on cold aerodynamic field test of supercritical 4 tangential firing boiler

刘建华 1马国伟 2白杨1

作者信息

  • 1. 宁夏电力能源科技有限公司,宁夏 银川 750011
  • 2. 国电科学技术研究院银川电力技术分院,宁夏 银川 750011
  • 折叠

摘要

Abstract

In order to understand the mixing and flow characteristics of airflow inside the furnace and around the burners under the thermal state operation,taking 660 MW supercritical 4 tangential firing boiler of a power plant in Ningxia as the research object,makes the boiler cold state aerodynamic field test including cold primary air leveling,characteristic test of secondary air inlet damper control,measuring and tracing for the cold aerodynamic field and velocity field inside the furnace. The test result shows that the wind speed of each layer burner nozzle is uniform,flame is full of furnace after air flow formed tangential,the center of the flame is in the centre of the furnace without decline. The test provides the reliable referrence for the thermal state operation and combustion regulating of the units.

关键词

超临界/四角切圆锅炉/空气动力场

Key words

supercritical/4 tangential firing boiler/aerodynamic field

分类

能源科技

引用本文复制引用

刘建华,马国伟,白杨..超临界四角切圆锅炉冷态空气动力场试验研究[J].宁夏电力,2014,(6):61-67,7.