宁夏电力Issue(2):60-64,5.DOI:10.3969/j.issn.1672-3643.2015.02.012
空预器热端传热元件失效的原因分析及措施
Cause analysis and countermeasures on the heat transfer component failure at hot end of air preheater
段小云1
作者信息
- 1. 广州中电荔新电力实业有限公司,广东 广州 511340
- 折叠
摘要
Abstract
Aiming at the problem of heat transfer component failure at hot end of No.1 boiler air preheater in Guangzhou Lixin Power Plant,by microscopic and macroscopic inspection analysis, finds the failure causes,makes corresponding improvement measure. The improvement result shows that by optimizing and adjusting soot blowing procedure,effectively solves the problem of damage and failure of air preheater component,ensures normal operation of boiler and units.关键词
锅炉空预器/传热元件/疲劳断裂Key words
air preheater of boiler/heat transfer component/fatigue fracture分类
能源科技引用本文复制引用
段小云..空预器热端传热元件失效的原因分析及措施[J].宁夏电力,2015,(2):60-64,5.