起重运输机械Issue(8):116-118,3.
腹板加高门式起重机的应力测试及分析
鞠成伟 1赵政飞1
作者信息
- 1. 广西特种设备监督检验院南宁 530219
- 折叠
摘要
Abstract
The 1 0a MQ gantry crane is used to heighten the web on the railway goods yard to increase the rated load;then 1 0a gantry crane is put into service again for analysis of static and dynamic test,to work out that the maximum static stress under rated load is at the root of cantilever on the right side of the southern beam;the reconstructed main beam still has ideal strength margin,able to meet the working demand for rated load;the dynamic response at the attachment weld of cover plate on the right side of 1/4 mid-span of south beam is most sensitive,which shall be brought to the forefront,requi-ring regular inspection.关键词
门式起重机/应力测试/腹板加高Key words
gantry crane/stress test/heightening web分类
机械制造引用本文复制引用
鞠成伟,赵政飞..腹板加高门式起重机的应力测试及分析[J].起重运输机械,2014,(8):116-118,3.