| 注册
首页|期刊导航|热力发电|煤气锅炉主要运行参数的煤耗偏差分析

煤气锅炉主要运行参数的煤耗偏差分析

叶亚兰 司风琪 徐治皋 江文豪

热力发电Issue(11):112-115,4.
热力发电Issue(11):112-115,4.DOI:10.3969/j.issn.1002-3364.2014.11.112

煤气锅炉主要运行参数的煤耗偏差分析

Coal consumption deviation analysis of main operation parameters in gas boilers

叶亚兰 1司风琪 2徐治皋 2江文豪3

作者信息

  • 1. 江苏海事职业技术学院轮机工程学院,江苏 南京 211170
  • 2. 东南大学能源热转换及其过程测控教育部重点实验室,江苏 南京 210096
  • 3. 中冶华天工程技术有限公司,江苏 南京 210000
  • 折叠

摘要

Abstract

If main operation parameters deviate from the target value,the boiler thermal efficiency will de-crease and the unit coal consumption will rise.Thus,the key points in calculating gas boiler thermal effi-ciency was analyzed,and the energy-loss analysis model which is suitable for gas boilers was put forward. Taking a 220 t/h blast furnace gas-fired boiler as the research object,the established model was adopted to calculate the coal consumption deviation resulted from the boiler operation parameters'variation,like the exhaust temperature,the oxygen content in exhaust,CO concentration in exhaust and so on.The results show this model can obtain the coal consumption deviation accurately,which provides a guidance for boiler optimization operation.

关键词

煤气锅炉/煤耗偏差/运行参数/热效率/煤耗

Key words

gas boiler/energy-loss analysis/operation parameters/thermal efficiency/coal consumption