Against the flue duct optimization after integration of induced draft fan and booster fan in thermal power plants,a numerical simulation based design method combining with the practical retrofitting experi-ence for flue duct optimization was put forward and then applied in the induced fan retrofitting for a 300 MW unit.The results show that optimizing the flue arrangement and adding appropriate guide plates lead to a pronounced energy-saving effect with reduced flue losses as well as improved flow uniformity at the inlet of the absorbing tower.关键词
引风机/增压风机/合并改造/烟道优化/导流板/烟道阻力/节能Key words
induced draft fan/booster fan/integration/flue optimization/guide plate/flue duct resistance/en-ergy saving分类