Agalnst the characteristics of low-temperature waste heat of flue gas and turbine exhaust steam in CFB power plants,process that using the low pressure economizer combining with the type Ⅰ absorption heat pump to recover low-temperature waste heat was proposed.On the basis of THA and rated extraction conditions of a 150 MW unit,relative calculation was carried out.The results show that,after adopting this heat recovery technology,under the above two working conditions,the unit power generating load increased by 2.37 MW and 2.97 MW,the circulating thermal efficiency enhanced by 0.51% and 0.60%,separately. Furthermore,the circulating water in cooling tower reduced,so that the heat load decreased.关键词
150 MW机组/低压省煤器/吸收式热泵/低温余热回收/热经济性Key words
150 MW unit/low pressure economizer/absorption heat pump/low-temperature waste heat re-covery/thermal efficiency分类
能源科技引用本文复制引用
赵斌,赵利杰,李佩,卢闪,吕俊复..电站低温余热回收工艺热经济性分析[J].热力发电,2015,(4):78-81,4.基金项目
河北省科学技术研究与发展计划项目(11213941) (11213941)