摘要
Abstract
Combined with the application of FRP pipe in pressure pipe of hydropower station, Diameter of pipe and the pressure rating are analyzed for the adjustment scheme from 700mm diameter spiral pipe to 600mm diameter FRP pipe in the upper of pressure pipe of Shimadai hydropower station. The results show that, in adjustment design scheme between 1# to 12# town pier 816. 8m pressure pipes using 600m diameter FRP pipe can meet the requirement of discharge capacity, and it is appropriate that pressure rating of FRP pipe is determined by 1. 5 times working water pressure, and it meets the requirements of the current codes and specification, Adjusted scheme is reasonable. Proposals from the review are references for the application of FRP pipe in pressure pipe of small hydropower station.关键词
玻璃钢管/压力管道/水电站/管径/压力等级Key words
FRP pipe/pressure pipe/hydropower station/diameter of pipe/pressure rating分类
建筑与水利引用本文复制引用
付成华,周洪波..玻璃钢管在水电站压力管道中的应用复核分析[J].西华大学学报(自然科学版),2015,(4):80-82,92,4.基金项目
西华大学流体及动力机械省部共建教育部重点实验室学术成果培育项目(SBZDPY-11-9) (SBZDPY-11-9)