中国伤残医学Issue(1):14-16,3.DOI:10.13214/j.cnki.cjotadm.2015.01.010
FUS-2000尿沉渣分析仪与显微镜检测尿液红细胞的对比分析
Contrast Analysis of Erythrocyte Detection in Urine by FUS-2000 Automatic Urine Sediment Analyzer and Microscope
王伟娟 1杨焦峰 2康丽霞 1郑辉 1孔玉凤1
作者信息
- 1. 新乡医学院第三附属医院检验科,河南 新乡 453003
- 2. 新乡医学院第二附属医院检验科
- 折叠
摘要
Abstract
Objective:To evaluate contrast analysis of two different ways of erythrocyte testing in urine.Methods:A total of 25212 sam-ples were detected by FUS-2000 analyzer and microscope respectively to test erythrocyte .Every samples detected by FUS-2000 analyzer must be amended by image and erythrocyte positive results were counted before and after image amendment .Results:The positive rate was 48.5%and 20.8%before and after image amendment and The positive rate of microscope examination was 20.3%.Coincidence rate of image amendment and microscope examination was 99.4%,but this rate of non-amendment and microscope examination was 71.8%. Conclusion:The image amendment was necessary when erythrocyte detected by FUS-2000 because of many effect factors.And the manu-al microscopy should be used for abnormal illegible cases.关键词
红细胞/FUS-2000尿沉渣分析仪/显微镜检查/对比分析Key words
Erythrocyte/FUS-2000Urine sediment analyzer/Microscope examination/Comparative analysis分类
医药卫生引用本文复制引用