| 注册
首页|期刊导航|生物医学工程研究|PV C输液器输注青霉素钠的相容性研究

PV C输液器输注青霉素钠的相容性研究

沈永 潘华先 刘爱娟 秦洋 李文丽 吴长岩

生物医学工程研究Issue(1):58-63,6.
生物医学工程研究Issue(1):58-63,6.

PV C输液器输注青霉素钠的相容性研究

Compatibility of Penicillin Sodium in the PVC Infusion

沈永 1潘华先 2刘爱娟 1秦洋 2李文丽 3吴长岩4

作者信息

  • 1. 山东省医疗器械产品质量检验中心,济南250100
  • 2. 山东省医疗器械生物学评价重点实验室,济南250100
  • 3. 山东省医疗器械生物学评价重点实验室,济南250100
  • 4. 山东恒信检测技术开发中心,济南250100
  • 折叠

摘要

Abstract

To analyze the leaching content from disposable infusion by simulating clinical use of Penicillin sodium injection.We used type A and B infusion from two different manufacturers.Drug adsorption and compound migrating were not found using HPLC. However,after the detection of GC-MS,cyclohexanone and DEHP were found in both of the two infusions,little isooctanol was also found in infusion A.These leaching contents were all introduced by the manufactor of the infusion,and the doses were far below the in-take of human body.This research shows that the use of disposable infusion for Penicillin sodium in clinical treatment takes a lower risk.

关键词

一次性使用输液器/可沥滤物/青霉素钠/相容性/邻苯二甲酸二辛酯

Key words

Disposable infusion/Leaching content/Penicillin sodium/Diethylhexyl Phthalate(DEHP)

分类

医药卫生

引用本文复制引用

沈永,潘华先,刘爱娟,秦洋,李文丽,吴长岩..PV C输液器输注青霉素钠的相容性研究[J].生物医学工程研究,2015,(1):58-63,6.

基金项目

国家科技支撑计划课题(2012BAI22B03)。 ()