In order to investigate the influence of intake elevation on the water temperature,discuss its sen⁃sibility, a full three-dimensional flow-temperature coupled mathematics model was established combined with Fengman station. At the same time, a physical model test was carried out, and the calculated results and experimental results were validated each other. Based on the research for different intake elevations with16.0~25.0 m,it is pointed that the water temperature was influenced by water head and water tempera⁃ture gradient in front of the dam. With the reduction of intake elevation,the temperature of discharged wa⁃ter increased. However, the growth of water temperature decreased gradually, which is independent of verti⁃cal gradient of water temperature. In case the elevation is larger than 240.0 m, the influence of old dam gap on discharged water temperature is little. The intake water head is suggested 16.0 ~ 18.0 m for large thermal stratified reservoir. However, the result was concluded only from single project, which should be further studied at other projects.

关键词

水电站/下泄水温/敏感性分析/三维数值模拟/水温物理模型

Key words

hydropower station/water temperature discharged/sensibility analysis/3D numerical simula-tion/physical model of water temperature

分类

资源环境

引用本文复制引用

郑铁刚,孙双科,柳海涛,戴会超,宗全利..大型分层型水库下泄水温对取水高程敏感性分析研究[J].水利学报,2015,(6):714-722,731,10.

基金项目

国家自然科学基金(51309256,51269028);长江学者和创新团队发展计划 ()

水利学报

OA北大核心CSCDCSTPCD

0559-9350

访问量0
|
下载量0
段落导航相关论文