| 注册
首页|期刊导航|现代检验医学杂志|湖北省临床化学常规检验项目不精密度分析

湖北省临床化学常规检验项目不精密度分析

潘莉兰 邓盼 祝卫平

现代检验医学杂志Issue(2):160-162,3.
现代检验医学杂志Issue(2):160-162,3.DOI:10.3969/j.issn.1671-7414.2015.02.051

湖北省临床化学常规检验项目不精密度分析

Analysis of the Imprecision of Clinical Routine Chemistry Analysis Tests in Hubei Province

潘莉兰 1邓盼 1祝卫平1

作者信息

  • 1. 湖北省临床检验中心,武汉 430064
  • 折叠

摘要

Abstract

Objective To learn how well these items of Hubei Province meet the quality standards of allowed imprecision. Methods Collected the indoor quality control data of median concentration levels from the laboratories which participated the project of interlaboratory comparisons of clinical chemistry indoor quality control data in Hubei Province.This paper was to analyze the variation coefficient of indoor quality control for 21 routine clinical chemistry examination items which were K,Na,Cl,TCa,P,GLu,Urea,UA,Cr,TP,Alb,TC,TG,ALT,AST,TBil,ALP,AMS,CK,LDH andγ-GT.The other objec-tive was to learn how well these items of Hubei Province meet the quality standards of allowed imprecision.Then took the 1/3 TEa,1/4 TEa,WS/T-403-2012 and minimum imprecision derived from biological variation as quality specification.And an-alyzed the percentage of laboratories in meeting the quality standards.Results The TG,ALT,CK and TBil in more than 50% of the participated laboratories could meet the quality standards of the 1/3 TEa,1/4 TEa,WS/T-403-2012 and the low-est appropriate imprecision derived from biological variation.The Cl and Cr in more than 50% of laboratories couldn’t meet the all above quality standards.The Na and TCa in all laboratories couldn’t meet the quality standards of best imprecision derived from biological variation.The evaluation criterion for qualified items setted was that the variation coefficient in more than 80% laboratories was less than the quality standard.Thus,the percentage of the items which meet the lowest quality standard of biological variation and the all 21 items was the most (66.7%).While the percentage of the items which met the quality standards of the WS/T403-2012 and the best biological variation was the least (14.3%).Conclusion In short,the values of indoor variation coefficient of the 21 items in laboratories which participated the project of interlaboratory compari-sons of clinical chemistry indoor quality control data generally met the requirements.But some items had a little higher de-gree of dispersion.The laboratories should set the appropriate imprecision levels based on the detection capability and quality standards and improve the quality of examination through continuous efforts.

关键词

临床化学/常规项目/不精密度

Key words

clinical chemistry/regular tests/imprecision

分类

医药卫生

引用本文复制引用

潘莉兰,邓盼,祝卫平..湖北省临床化学常规检验项目不精密度分析[J].现代检验医学杂志,2015,(2):160-162,3.

现代检验医学杂志

OACSTPCD

1671-7414

访问量0
|
下载量0
段落导航相关论文