中国组织工程研究Issue(22):3481-3486,6.DOI:10.3969/j.issn.2095-4344

构建前柱钢板髋臼区安全置钉的三维模型

Construction of three-dimensional model of safe screwing in acetabular area of anterior column plate

宋迎春 1王钢 1卢超 1高波华1

作者信息

  • 1. 南方医科大学南方医院创伤骨科,广东省广州市 510515
  • 折叠

摘要

Abstract

BACKGROUND:During open reduction and plate fixation for acetabular anterior column fracture, screw penetrating the articular surface often occurred. To prevent this complication, quantitative anatomical measurement is very important for safe pedicle screw in acetabular area using anterior column plate technology. <br> OBJECTIVE:To provide anatomical basis for screwing placement safely in acetabular anterior column plate. <br> METHODS:Mimics Software was used to perform three-dimensional reconstruction of the 40 cases of male pelvic and 40 cases of female pelvic CT scan data. The cutting tool was used to make serial cross-sections of the acetabular anterior column and the measuring tool was used to determine the safe length and direction of screw entry on al entry points of each cross-section. Al data were uploaded into SPSS 13.0 software for statistics process. <br> RESULTS AND CONCLUSION: The distance from anterior acetabular margin to posterior acetabular margin and iliopubic eminence was as folows: in males: (56.63±2.05) mm, (12.30±1.51) mm, and in females: (49.07±5.07) mm, (16.93±1.74) mm, respectively. The distance from posterior acetabular margin to iliopubic eminence was as folows: in males: (45.46±3.44) mm, and in females: (33.72±6.85) mm. The safe entry angle of screws to iliac plate in the sagittal plane was (72.17±0.93)° in males, and (81.05±0.92)° in females. On each section of B, C and D, the maximum of the safe entry angle of screws to iliac plate in the oblique coronal plane was (53.88±3.01)°, (43.22±1.86)°, (54.60±2.97)° in males; and (49.54±1.81)°, (39.10±1.22)°, (47.91±2.23)° in females, respectively. Results indicated that three-dimensional model can be used to measure anatomic characteristics of acetabular anterior column plate and has important instruction significance for avoiding screwing into joint in acetabular anterior column plate technique.

关键词

植入物/骨植入物/数字化骨科/髋臼骨折/内固定/前柱钢板/解剖

Key words

prostheses and implants/acetabulum/fractures, bone/internal fixators

分类

医药卫生

引用本文复制引用

宋迎春,王钢,卢超,高波华..构建前柱钢板髋臼区安全置钉的三维模型[J].中国组织工程研究,2014,(22):3481-3486,6.

中国组织工程研究

OA北大核心CSTPCD

2095-4344

访问量5
|
下载量0
段落导航相关论文